    {"datasetrec":{"DasID":8768,"Acronym":null,"StandardTitle":"Monitoring of physicochemical water quality in the Demer River to determine impact of restored meanders between 2021 and 2024","OrigTitle":null,"OrigTitleLangID":null,"OrigTitleLangCode":null,"OrigTitleLang":null,"OrigTitleLangNL":null,"VersionName":null,"ContactEmail":null,"VersionDate":null,"VersionDay":null,"VersionMonth":null,"VersionYear":null,"SizeReference":null,"EngAbstract":"<p>This study examined the impact of meander reconnection and deflector placement on water quality.</p>","EngDescr":null,"OrigAbstract":null,"OrigDescr":null,"Comments":null,"ReleaseDate":null,"ReleaseDate0":null,"OrigDescrLang":null,"EmbargoDate":null,"OrigDescrLangNL":null,"OrigLangCode":null,"OrigLangCodeExtended":null,"OrigLangID":null,"DescrCompFlag":null,"DescrTransFlag":null,"Citation":"Hons, M.; Maris, T.; Schoelynck, J.; Ecosphere Research Group, University of Antwerp: Belgium; (2025): Monitoring of physicochemical water quality in the Demer River to determine impact of restored meanders between 2021 and 2024. Marine Data Archive.","AccessConstraints":null,"UDate":"2025-03-07","CDate":"2025-03-07","CurrencyDate":null,"RevisionDate":null,"DateLastModified":{"date":"2025-03-25 09:45:08.840000","timezone_type":1,"timezone":"+00:00"},"CheckedFlag":1,"PublicFlag":1,"VlizCoreFlag":1,"MarineFlag":0,"FreshFlag":null,"BrackishFlag":0,"TerrestrialFlag":0,"StatusID":1,"DasType":"Data","DasTypeID":1,"DasOrigin":"Monitoring: field survey","Progress":"Completed","AccessConstraint":"Attribution (CC BY)","AccConstrEN":"Attribution (CC BY)","AccConstrDisplay":"<a rel=\"license\" href=\"https://creativecommons.org/licenses/by/4.0/\" target=\"_blank\"><img alt=\"Creative Commons License\" style=\"border:0px;height:15px;width:80px;vertical-align:middle;\" src=\"https://www.marinespecies.org/aphia/images/cc/by.png\" /></a> This dataset is licensed under a <a rel=\"license\" href=\"https://creativecommons.org/licenses/by/4.0/\" target=\"_blank\">Creative Commons Attribution 4.0 International License</a>.","License":"https://creativecommons.org/licenses/by/4.0/","AccConstrDescription":"This license lets others distribute, remix, tweak, and build upon your work, even commercially, as long as they credit you for the original creation. This is the most accommodating of licenses offered. Recommended for maximum dissemination and use of licensed materials.","Lineage":null,"AccConID":21},"dois":null,"spcols":null,"keywords":[{"ThesaurusTerm":"Deflector installation","ThesTypID":0,"ThesType":null,"Code":null,"Description":null,"OrigThesTerm":"Deflector installation","DutchTerm":"","URI":null,"DasKeywordDescr":null},{"ThesaurusTerm":"Meander reconnection","ThesTypID":0,"ThesType":null,"Code":null,"Description":null,"OrigThesTerm":"Meander reconnection","DutchTerm":"","URI":null,"DasKeywordDescr":null},{"ThesaurusTerm":"Monitoring","ThesTypID":1,"ThesType":"ASFA Thesaurus List","Code":"c_4911","Description":null,"OrigThesTerm":"Monitoring","DutchTerm":"Monitoring","URI":"http://aims.fao.org/aos/agrovoc/c_4911","DasKeywordDescr":null},{"ThesaurusTerm":"Physicochemical water quality","ThesTypID":0,"ThesType":null,"Code":null,"Description":null,"OrigThesTerm":"Physicochemical water quality","DutchTerm":"","URI":null,"DasKeywordDescr":null},{"ThesaurusTerm":"River restoration","ThesTypID":0,"ThesType":null,"Code":null,"Description":null,"OrigThesTerm":"River restoration","DutchTerm":null,"URI":null,"DasKeywordDescr":null}],"parents":null,"children":null,"othrel":null,"othrelrev":null,"ownerships":[{"OrderNr":1,"Surname":"Hons","Firstname":"Malaurie","Initials":"M.","PerPublicFlag":1,"AdrID":null,"Email":null,"InsPublicFlag":1,"Acronym":null,"OrigNameLangCode":"en","OrigNameLangID":15,"FullOrigName":"University of Antwerp; Faculty of Sciences; Department of Biology; ECOSPHERE","InsOwnerCNT":5,"PersID":45735,"InsID":15083,"FullInstitute":"Universiteit Antwerpen; Faculteit Wetenschappen; Departement Biologie; ECOSPHERE","RoleID":24,"Role":"Contact","OrigName":"ECOSPHERE","StandardName":"ECOSPHERE","FullAcronym":"UA","ORC":"https://orcid.org/0000-0002-3107-1210","ROR":null},{"OrderNr":2,"Surname":"Hons","Firstname":"Malaurie","Initials":"M.","PerPublicFlag":1,"AdrID":null,"Email":null,"InsPublicFlag":1,"Acronym":null,"OrigNameLangCode":"en","OrigNameLangID":15,"FullOrigName":"University of Antwerp; Faculty of Sciences; Department of Biology; ECOSPHERE","InsOwnerCNT":5,"PersID":45735,"InsID":15083,"FullInstitute":"Universiteit Antwerpen; Faculteit Wetenschappen; Departement Biologie; ECOSPHERE","RoleID":61,"Role":"Data creator","OrigName":"ECOSPHERE","StandardName":"ECOSPHERE","FullAcronym":"UA","ORC":"https://orcid.org/0000-0002-3107-1210","ROR":null},{"OrderNr":3,"Surname":"Maris","Firstname":"Tom","Initials":"T.","PerPublicFlag":1,"AdrID":null,"Email":null,"InsPublicFlag":1,"Acronym":null,"OrigNameLangCode":"en","OrigNameLangID":15,"FullOrigName":"University of Antwerp; Faculty of Sciences; Department of Biology; ECOSPHERE","InsOwnerCNT":5,"PersID":7232,"InsID":15083,"FullInstitute":"Universiteit Antwerpen; Faculteit Wetenschappen; Departement Biologie; ECOSPHERE","RoleID":61,"Role":"Data creator","OrigName":"ECOSPHERE","StandardName":"ECOSPHERE","FullAcronym":"UA","ORC":"https://orcid.org/0000-0002-9819-6771","ROR":null},{"OrderNr":4,"Surname":"Schoelynck","Firstname":"Jonas","Initials":"J.","PerPublicFlag":1,"AdrID":170284,"Email":"jonas.schoelynck@uantwerpen.be","InsPublicFlag":1,"Acronym":null,"OrigNameLangCode":"en","OrigNameLangID":15,"FullOrigName":"University of Antwerp; Faculty of Sciences; Department of Biology; ECOSPHERE","InsOwnerCNT":5,"PersID":19314,"InsID":15083,"FullInstitute":"Universiteit Antwerpen; Faculteit Wetenschappen; Departement Biologie; ECOSPHERE","RoleID":61,"Role":"Data creator","OrigName":"ECOSPHERE","StandardName":"ECOSPHERE","FullAcronym":"UA","ORC":"https://orcid.org/0000-0003-0166-280X","ROR":null},{"OrderNr":5,"Surname":null,"Firstname":null,"Initials":null,"PerPublicFlag":null,"AdrID":null,"Email":null,"InsPublicFlag":1,"Acronym":null,"OrigNameLangCode":"en","OrigNameLangID":15,"FullOrigName":"University of Antwerp; Faculty of Sciences; Department of Biology; ECOSPHERE","InsOwnerCNT":5,"PersID":null,"InsID":15083,"FullInstitute":"Universiteit Antwerpen; Faculteit Wetenschappen; Departement Biologie; ECOSPHERE","RoleID":61,"Role":"Data creator","OrigName":"ECOSPHERE","StandardName":"ECOSPHERE","FullAcronym":"UA","ORC":null,"ROR":null}],"taxterms":null,"frameworks":null,"otherterms":[{"OtherTerm":"Deflector installation"},{"OtherTerm":"Meander reconnection"},{"OtherTerm":"Physicochemical water quality"},{"OtherTerm":"River restoration"}],"temporal":[{"DasDateID":6331,"StartYear":2021,"EndYear":2023,"StartDay":30,"EndDay":10,"StartDate":"2021-06-30","EndDate":"2023-10-10","DasDate":null,"Resolution":"Other","ResolutionNL":"Andere","Notes":"10 times a year, with some additional measurements in march 2023","StartMonth0":6,"StartMonth":"June","StartMonthNL":"Juni","EndMonth0":10,"EndMonth":"October","EndMonthNL":"Oktober","Progress":"Completed","ProgressNL":"Afgelopen"}],"geographical":[{"GeoTerm":"Demer R.","DasGeoID":14854,"DasGeoTerm":null,"DasID":8768,"GeotID":6563,"X":null,"Y":null,"MaxX":null,"MaxY":null,"StationName":null,"Precision":null,"CoordSystID":null,"GeoDatumID":null,"OrigCoordMinX":null,"OrigCoordMinY":null,"OrigCoordMaxX":null,"OrigCoordMaxY":null,"OrderNr":null,"Projection":null,"GeoDatum":null,"GeoObjectID":3101,"OrigGeoTerm":"Demer R.","DutchTerm":"Demer R."}],"meastypes":[{"MethID":737,"DasMeasTypID":20426,"DasMeasType":"","Matrix":null,"MatrixNL":null,"Parameter":"Ammonium (NH<sub>4</sub><sup>+</sup>)","ParameterNL":"Ammonium","Description":null,"Unit":"mg/l","Methodology":"Segmented Flow Analyser (Skalar San)","Protocol":null,"QualityControl":null,"Precision":null,"Detectionlimit":null,"Instrument":null,"InstrumentUrl":null,"MethFull":"","ParaCategoryTitle":null,"ParaCatCode":null},{"MethID":737,"DasMeasTypID":20426,"DasMeasType":"","Matrix":null,"MatrixNL":null,"Parameter":"Ammonium (NH<sub>4</sub><sup>+</sup>)","ParameterNL":"Ammonium","Description":null,"Unit":"mg/l","Methodology":"Segmented Flow Analyser (Skalar San)","Protocol":null,"QualityControl":null,"Precision":null,"Detectionlimit":null,"Instrument":null,"InstrumentUrl":null,"MethFull":"","ParaCategoryTitle":null,"ParaCatCode":null},{"MethID":738,"DasMeasTypID":20429,"DasMeasType":"","Matrix":null,"MatrixNL":null,"Parameter":"Biogenic silica","ParameterNL":"Biogene silica","Description":null,"Unit":"mg/l","Methodology":"Inductively Coupled Plasma Emission Spectrophotometer (ICP-OES) from Thermo Scientific iCAP 6300 DUO.","Protocol":null,"QualityControl":null,"Precision":null,"Detectionlimit":null,"Instrument":null,"InstrumentUrl":null,"MethFull":"","ParaCategoryTitle":null,"ParaCatCode":null},{"MethID":734,"DasMeasTypID":20420,"DasMeasType":"","Matrix":null,"MatrixNL":null,"Parameter":"Carbonaceous oxygen demand","ParameterNL":null,"Description":null,"Unit":"mg/l","Methodology":"Dilution with oxygen rich water, added an inhibitor (allylthioureum) to surpress nitrification. 5 days incubations. Measurement of oxygen before and after incubation.","Protocol":null,"QualityControl":null,"Precision":null,"Detectionlimit":null,"Instrument":null,"InstrumentUrl":null,"MethFull":"","ParaCategoryTitle":null,"ParaCatCode":null},{"MethID":739,"DasMeasTypID":20432,"DasMeasType":"","Matrix":null,"MatrixNL":null,"Parameter":"Chlorophyll a","ParameterNL":"Chlorofyl a","Description":"Chlorophyl a content","Unit":"mg/l","Methodology":"Organic plant material is removed from the water by filtration over a glass fibre filter. Pigments are extracted from the algal cells with acetone 90% and then estimated spectrophotometrically at 750, 664/665, 645, 630 and 480 nm.","Protocol":null,"QualityControl":null,"Precision":null,"Detectionlimit":null,"Instrument":null,"InstrumentUrl":null,"MethFull":"","ParaCategoryTitle":null,"ParaCatCode":null},{"MethID":731,"DasMeasTypID":20417,"DasMeasType":"","Matrix":null,"MatrixNL":null,"Parameter":"Conductivity","ParameterNL":"Conductiviteit","Description":null,"Unit":"µS/cm","Methodology":"in-field measurement with WTW multiparameter instrument","Protocol":null,"QualityControl":null,"Precision":null,"Detectionlimit":null,"Instrument":null,"InstrumentUrl":null,"MethFull":"","ParaCategoryTitle":null,"ParaCatCode":null},{"MethID":736,"DasMeasTypID":20422,"DasMeasType":"","Matrix":null,"MatrixNL":null,"Parameter":"Dissolved organic carbon (DOC)","ParameterNL":"Opgeloste organische koolstof","Description":null,"Unit":"mg/l","Methodology":"Colorimetric with Skalar San+","Protocol":null,"QualityControl":null,"Precision":null,"Detectionlimit":null,"Instrument":null,"InstrumentUrl":null,"MethFull":"","ParaCategoryTitle":null,"ParaCatCode":null},{"MethID":731,"DasMeasTypID":20414,"DasMeasType":"","Matrix":null,"MatrixNL":null,"Parameter":"Dissolved oxygen (O2)","ParameterNL":"Opgeloste zuurstof","Description":"Dissolved oxygen NIOO-CEME parameter ","Unit":"mg/l","Methodology":"in-field measurement with WTW multiparameter instrument","Protocol":null,"QualityControl":null,"Precision":null,"Detectionlimit":null,"Instrument":null,"InstrumentUrl":null,"MethFull":"","ParaCategoryTitle":null,"ParaCatCode":null},{"MethID":738,"DasMeasTypID":20430,"DasMeasType":"","Matrix":null,"MatrixNL":null,"Parameter":"Dissolved Silica","ParameterNL":"Opgelost silica","Description":null,"Unit":"mg/l","Methodology":"Inductively Coupled Plasma Emission Spectrophotometer (ICP-OES) from Thermo Scientific iCAP 6300 DUO.","Protocol":null,"QualityControl":null,"Precision":null,"Detectionlimit":null,"Instrument":null,"InstrumentUrl":null,"MethFull":"","ParaCategoryTitle":null,"ParaCatCode":null},{"MethID":737,"DasMeasTypID":20423,"DasMeasType":"","Matrix":null,"MatrixNL":null,"Parameter":"Kjeldahl nitrogen","ParameterNL":null,"Description":null,"Unit":"mg/l","Methodology":"Segmented Flow Analyser (Skalar San)","Protocol":null,"QualityControl":null,"Precision":null,"Detectionlimit":null,"Instrument":null,"InstrumentUrl":null,"MethFull":"","ParaCategoryTitle":null,"ParaCatCode":null},{"MethID":737,"DasMeasTypID":20424,"DasMeasType":"","Matrix":null,"MatrixNL":null,"Parameter":"Nitrate (NO<sub>3</sub><sup>-</sup>)","ParameterNL":"Nitraat  (NO3-)","Description":"PO<sub>4</sub><sup>3-</sup>)","Unit":"mg/l","Methodology":"Segmented Flow Analyser (Skalar San)","Protocol":null,"QualityControl":null,"Precision":null,"Detectionlimit":null,"Instrument":null,"InstrumentUrl":null,"MethFull":"","ParaCategoryTitle":null,"ParaCatCode":null},{"MethID":737,"DasMeasTypID":20424,"DasMeasType":"","Matrix":null,"MatrixNL":null,"Parameter":"Nitrate (NO<sub>3</sub><sup>-</sup>)","ParameterNL":"Nitraat  (NO3-)","Description":"PO<sub>4</sub><sup>3-</sup>)","Unit":"mg/l","Methodology":"Segmented Flow Analyser (Skalar San)","Protocol":null,"QualityControl":null,"Precision":null,"Detectionlimit":null,"Instrument":null,"InstrumentUrl":null,"MethFull":"","ParaCategoryTitle":null,"ParaCatCode":null},{"MethID":737,"DasMeasTypID":20425,"DasMeasType":"","Matrix":null,"MatrixNL":null,"Parameter":"Nitrite (NO<sub>2</sub><sup>-</sup>)","ParameterNL":"Nitriet  (NO2-)","Description":null,"Unit":"mg/l","Methodology":"Segmented Flow Analyser (Skalar San)","Protocol":null,"QualityControl":null,"Precision":null,"Detectionlimit":null,"Instrument":null,"InstrumentUrl":null,"MethFull":"","ParaCategoryTitle":null,"ParaCatCode":null},{"MethID":737,"DasMeasTypID":20425,"DasMeasType":"","Matrix":null,"MatrixNL":null,"Parameter":"Nitrite (NO<sub>2</sub><sup>-</sup>)","ParameterNL":"Nitriet  (NO2-)","Description":null,"Unit":"mg/l","Methodology":"Segmented Flow Analyser (Skalar San)","Protocol":null,"QualityControl":null,"Precision":null,"Detectionlimit":null,"Instrument":null,"InstrumentUrl":null,"MethFull":"","ParaCategoryTitle":null,"ParaCatCode":null},{"MethID":737,"DasMeasTypID":20428,"DasMeasType":"","Matrix":null,"MatrixNL":null,"Parameter":"Orthophosphate (o-PO<sub>4</sub><sup>3-</sup>)","ParameterNL":"Orthofosfaat","Description":null,"Unit":"mg/l","Methodology":"Segmented Flow Analyser (Skalar San)","Protocol":null,"QualityControl":null,"Precision":null,"Detectionlimit":null,"Instrument":null,"InstrumentUrl":null,"MethFull":"","ParaCategoryTitle":null,"ParaCatCode":null},{"MethID":731,"DasMeasTypID":20416,"DasMeasType":"","Matrix":null,"MatrixNL":null,"Parameter":"pH","ParameterNL":"pH-zuurtegraad","Description":null,"Unit":null,"Methodology":"in-field measurement with WTW multiparameter instrument","Protocol":null,"QualityControl":null,"Precision":null,"Detectionlimit":null,"Instrument":null,"InstrumentUrl":null,"MethFull":"","ParaCategoryTitle":null,"ParaCatCode":null},{"MethID":739,"DasMeasTypID":20433,"DasMeasType":"","Matrix":null,"MatrixNL":null,"Parameter":"Phaeopigments","ParameterNL":null,"Description":null,"Unit":"mg/l","Methodology":"Organic plant material is removed from the water by filtration over a glass fibre filter. Pigments are extracted from the algal cells with acetone 90% and then estimated spectrophotometrically at 750, 664/665, 645, 630 and 480 nm.","Protocol":null,"QualityControl":null,"Precision":null,"Detectionlimit":null,"Instrument":null,"InstrumentUrl":null,"MethFull":"","ParaCategoryTitle":null,"ParaCatCode":null},{"MethID":739,"DasMeasTypID":20433,"DasMeasType":"","Matrix":null,"MatrixNL":null,"Parameter":"Phaeopigments","ParameterNL":null,"Description":null,"Unit":"mg/l","Methodology":"Organic plant material is removed from the water by filtration over a glass fibre filter. Pigments are extracted from the algal cells with acetone 90% and then estimated spectrophotometrically at 750, 664/665, 645, 630 and 480 nm.","Protocol":null,"QualityControl":null,"Precision":null,"Detectionlimit":null,"Instrument":null,"InstrumentUrl":null,"MethFull":"","ParaCategoryTitle":null,"ParaCatCode":null},{"MethID":731,"DasMeasTypID":20431,"DasMeasType":"","Matrix":null,"MatrixNL":null,"Parameter":"Saturated oxygen","ParameterNL":null,"Description":null,"Unit":"%","Methodology":"in-field measurement with WTW multiparameter instrument","Protocol":null,"QualityControl":null,"Precision":null,"Detectionlimit":null,"Instrument":null,"InstrumentUrl":null,"MethFull":"","ParaCategoryTitle":null,"ParaCatCode":null},{"MethID":733,"DasMeasTypID":20419,"DasMeasType":"","Matrix":null,"MatrixNL":null,"Parameter":"Suspended particulate matter (SPM)","ParameterNL":"Zwevende stof","Description":null,"Unit":"mg/l","Methodology":"lab measurement by filtration of 3x50 ml on a Whatmann GF/F 0.7 µm filter","Protocol":null,"QualityControl":null,"Precision":null,"Detectionlimit":null,"Instrument":null,"InstrumentUrl":null,"MethFull":"","ParaCategoryTitle":null,"ParaCatCode":null},{"MethID":735,"DasMeasTypID":20421,"DasMeasType":"","Matrix":null,"MatrixNL":null,"Parameter":"Total organic carbon (TOC)","ParameterNL":null,"Description":null,"Unit":"mg/l","Methodology":"Lab measurement by filtration of 3x50 ml on a Whatmann GF/F 0.7 µm filter. Incenaration of filter for 4h at 550°C (LOI).","Protocol":null,"QualityControl":null,"Precision":null,"Detectionlimit":null,"Instrument":null,"InstrumentUrl":null,"MethFull":"","ParaCategoryTitle":null,"ParaCatCode":null},{"MethID":737,"DasMeasTypID":20427,"DasMeasType":"","Matrix":null,"MatrixNL":null,"Parameter":"Total phosphorus (P)","ParameterNL":"Totaal Fosfor (P)","Description":null,"Unit":"mg/l","Methodology":"Segmented Flow Analyser (Skalar San)","Protocol":null,"QualityControl":null,"Precision":null,"Detectionlimit":null,"Instrument":null,"InstrumentUrl":null,"MethFull":"","ParaCategoryTitle":null,"ParaCatCode":null},{"MethID":732,"DasMeasTypID":20418,"DasMeasType":"","Matrix":null,"MatrixNL":null,"Parameter":"Turbidity","ParameterNL":"Turbiditeit","Description":null,"Unit":"NTU","Methodology":"in-field measurement with nephelometer","Protocol":null,"QualityControl":null,"Precision":null,"Detectionlimit":null,"Instrument":null,"InstrumentUrl":null,"MethFull":"","ParaCategoryTitle":null,"ParaCatCode":null},{"MethID":731,"DasMeasTypID":20415,"DasMeasType":"","Matrix":null,"MatrixNL":null,"Parameter":"Water temperature","ParameterNL":"Watertemperatuur","Description":null,"Unit":"°C","Methodology":"in-field measurement with WTW multiparameter instrument","Protocol":null,"QualityControl":null,"Precision":null,"Detectionlimit":null,"Instrument":null,"InstrumentUrl":null,"MethFull":"","ParaCategoryTitle":null,"ParaCatCode":null}],"dasthemes":[{"DasThemeID":7,"DasTheme":"Physical","DasTheme0":"Physical","DutchTerm":"Fysisch"},{"DasThemeID":15,"DasTheme":"Water composition","DasTheme0":"Water composition","DutchTerm":"Watersamenstelling"}],"projects":null,"refs":[{"0":405984,"BRefID":405984,"1":"Based on this dataset","Relation":"Based on this dataset","2":2,"RelationID":2,"3":"<b>Hons, M.; Maris, T.; Schoelynck, J.</b> (2025). The effects of meander reconnection and deflector installation on the physicochemical water quality. <i>\tRiver Res. Applic. 41(1)</i>: 56-67. <a href=\"https://dx.doi.org/10.1002/rra.4384\" target=\"_blank\">https://dx.doi.org/10.1002/rra.4384</a>","RR":"<b>Hons, M.; Maris, T.; Schoelynck, J.</b> (2025). The effects of meander reconnection and deflector installation on the physicochemical water quality. <i>\tRiver Res. Applic. 41(1)</i>: 56-67. <a href=\"https://dx.doi.org/10.1002/rra.4384\" target=\"_blank\">https://dx.doi.org/10.1002/rra.4384</a>","4":"The effects of meander reconnection and deflector installation on the physicochemical water quality","StT":"The effects of meander reconnection and deflector installation on the physicochemical water quality","5":"Hons, M.; Maris, T.; Schoelynck, J.","RSA":"Hons, M.; Maris, T.; Schoelynck, J.","6":"Gebaseerd op deze dataset","DutchTerm":"Gebaseerd op deze dataset","7":2025,"AnaDate":2025,"8":null,"MonDate":null,"9":". <i>\tRiver Res. Applic. 41(1)</i>: 56-67. <a href=\"https://dx.doi.org/10.1002/rra.4384\" target=\"_blank\">https://dx.doi.org/10.1002/rra.4384</a>","":". <i>\tRiver Res. Applic. 41(1)</i>: 56-67. <a href=\"https://dx.doi.org/10.1002/rra.4384\" target=\"_blank\">https://dx.doi.org/10.1002/rra.4384</a>","10":"https://dx.doi.org/10.1002/rra.4384","doi":"https://dx.doi.org/10.1002/rra.4384"}],"urls":null,"pictures":null,"urlmaps":null,"spatreps":null,"fileformats":null,"resmessage":"","complete":1}
