{"refrec":{"BRefID":19614,"RR":"<b>Suantika, G.; Dhert, P.; Rombaut, G.; Vandenberghe, J.; De Wolf, T.; Sorgeloos, P.</b> (2001). The use of ozone in a high density recirculation system for rotifers. <i>Aquaculture 201(1-2)</i>: 35-49. <a href=\"http://dx.doi.org/10.1016/S0044-8486(01)00532-4\" target=\"_blank\">dx.doi.org/10.1016/S0044-8486(01)00532-4</a>","BEntID":19614,"PublicFlag":1,"CheckedFlag":0,"wosflag":1,"vabbflag":null,"RefStringPartII":". <i>Aquaculture 201(1-2)</i>: 35-49. <a href=\"https://dx.doi.org/10.1016/S0044-8486(01)00532-4\" target=\"_blank\">https://dx.doi.org/10.1016/S0044-8486(01)00532-4</a>","DocTypID":8,"DocType":"Journal article","MarineFlag":1,"FreshFlag":1,"BrackishFlag":1,"TerrestrialFlag":0,"Authorstring":"Suantika, G.; Dhert, P.; Rombaut, G.; Vandenberghe, J.; De Wolf, T.; Sorgeloos, P.","OrigTitleTranslFlag":0,"Authorstringtrunc":"Suantika, G. <i>et al.</i>","Englishabstract":"The use of ozone in the effluent treatment of a closed recirculation system for rotifers resulted in a significant improvement of rotifer production and water quality. Compared to a control treatment, the rotifer culture exposed to ozone did not only support a higher rotifer biomass (16000 vs. 8000 rotifers ml<sup>-1</sup>), it also allowed a prolongation of the culture period for 4 days. Compared to a control treatment, the ammonium levels were reduced by 67%, nitrite levels by 85% and nitrate levels by 67%. The supplementation of ozone did not affect pH and dissolved oxygen levels. Besides the positive effect of ozone to the nitrification process, a better removal of suspended solids was noticed as well. This resulted in a decreased turbidity and a reduction of the number of particles in the culture water. The use of ozone also reduced the number of bacteria in the culture water. In general terms, it can be stated that supplementation of ozone in a closed recirculation system for rotifers considerably improves water quality, ensures stable and longer rotifer culture periods and controls bacterial proliferation.","AbstractOtherLang":null,"BibLvlCode":"AS","StandardTitle":"The use of ozone in a high density recirculation system for rotifers","OrigTitleLangCode":"en","OrigTitleLangCodeExtended":"eng","OrigTitleLangID":15,"DateLastModified":{"date":"2024-12-10 01:33:17.368041","timezone_type":1,"timezone":"+01:00"},"UserAccessRight":null,"UserAccID":null,"AuthorKeywords":"Brachionus plicatilis; recirculation; ozone; rotifers","OtherDescriptors":"<i>Brachionus plicatilis</i>; Recirculation; Ozone; RotifersOzone; Recirculating systems; Water quality control; Aquaculture techniques; Suspended particulate matter; Dissolved oxygen; Nitrification; Bacteria; Rotifera","Notes":null,"AnaPub":2001,"MonPub":null,"DateUpdate":"2015-10-27","DateCreate":"2001-10-12","SecASFANote":null,"ConfID":null,"PeerRev":1,"VlizCoreFlag":1,"WoScode":"WOS:000171063100003","VABBcode":null,"OpenAcc":0,"DOI":"10.1016/S0044-8486(01)00532-4"},"refs":null,"anarec":{"AnaID":19614,"PubliDate":2001,"Pagination":"35-49","XtraPublOfAnaID":null,"ISBN":null,"Volume":"201","Issue":"1-2","BRefMon":null,"BRefMonRR":null,"BRefXtra":null,"BRefXtraRR":null,"SerBRefID":42190,"SerRR":"Aquaculture. Elsevier: Amsterdam; London; New York; Oxford; Tokyo.  ISSN 0044-8486; e-ISSN 1873-5622","StandardTitleSer":"Aquaculture","ISSN":"0044-8486","AbbrevSer":"Aquaculture","StandardTitleMon":null,"StartPage":35,"Pages":15,"ToPubliDate":null,"BRefBibLvlCode":"S","SerNotes":null},"monrec":null,"serrec":null,"relations":null,"relationsRev":null,"addrec":{"Line1":"Rozier 44","Email":"gede.suantika@ugent.be","Line2":null,"EnvName":"Belgium"},"othpubs":null,"ownerships":null,"authors":[{"AutName":"Suantika","Firstname":"Gede","Initials":"G.","Affiliation":"Laboratory of Aquaculture and Artemia Reference Center, Ghent University","Discriminator":null,"CorporateFlag":0,"BEntID":19614,"AutID":143940,"OrderNr":1,"DegrID":null,"EditorFlag":0,"CorrespFlag":0,"IllustratorFlag":0,"ReviserFlag":0,"TranslatorFlag":0,"InsAcronym":"ARC","InsFSN":"Universiteit Gent; Faculteit Bio-ingenieurswetenschappen; Vakgroep Dierwetenschappen en Aquatische Ecologie; Laboratorium voor Aquacultuur en Artemia Reference Center","ORCID":null,"PersID":2563,"InsID":22},{"AutName":"Dhert","Firstname":"Philippe","Initials":"P.","Affiliation":"Laboratory of Aquaculture and Artemia Reference Center, Ghent University","Discriminator":null,"CorporateFlag":0,"BEntID":19614,"AutID":143938,"OrderNr":2,"DegrID":null,"EditorFlag":0,"CorrespFlag":0,"IllustratorFlag":0,"ReviserFlag":0,"TranslatorFlag":0,"InsAcronym":"ARC","InsFSN":"Universiteit Gent; Faculteit Bio-ingenieurswetenschappen; Vakgroep Dierwetenschappen en Aquatische Ecologie; Laboratorium voor Aquacultuur en Artemia Reference Center","ORCID":null,"PersID":112,"InsID":22},{"AutName":"Rombaut","Firstname":"Geert","Initials":"G.","Affiliation":"Laboratory of Microbial Ecology and Technology, Ghent University","Discriminator":null,"CorporateFlag":0,"BEntID":19614,"AutID":147906,"OrderNr":3,"DegrID":null,"EditorFlag":0,"CorrespFlag":0,"IllustratorFlag":0,"ReviserFlag":0,"TranslatorFlag":0,"InsAcronym":"CMET","InsFSN":"Ghent University; Faculty of Bioscience Engineering; Department of Biotechnology; Center for Microbial Ecology and Technology","ORCID":null,"PersID":3641,"InsID":6702},{"AutName":"Vandenberghe","Firstname":null,"Initials":"J.","Affiliation":"Laboratory for Microbiology","Discriminator":null,"CorporateFlag":0,"BEntID":19614,"AutID":144760,"OrderNr":4,"DegrID":null,"EditorFlag":0,"CorrespFlag":0,"IllustratorFlag":0,"ReviserFlag":0,"TranslatorFlag":0,"InsAcronym":null,"InsFSN":"Universiteit Gent; Faculteit Wetenschappen; Vakgroep Biochemie en Microbiologie; Laboratorium voor Microbiologie","ORCID":null,"PersID":null,"InsID":1605},{"AutName":"De Wolf","Firstname":null,"Initials":"T.","Affiliation":"INVE Technologies","Discriminator":null,"CorporateFlag":0,"BEntID":19614,"AutID":144761,"OrderNr":5,"DegrID":null,"EditorFlag":0,"CorrespFlag":0,"IllustratorFlag":0,"ReviserFlag":0,"TranslatorFlag":0,"InsAcronym":null,"InsFSN":"Inve Technologies NV","ORCID":null,"PersID":null,"InsID":203},{"AutName":"Sorgeloos","Firstname":"Patrick","Initials":"P.","Affiliation":"Laboratory of Aquaculture and Artemia Reference Center, Ghent University","Discriminator":null,"CorporateFlag":0,"BEntID":19614,"AutID":143941,"OrderNr":6,"DegrID":null,"EditorFlag":0,"CorrespFlag":0,"IllustratorFlag":0,"ReviserFlag":0,"TranslatorFlag":0,"InsAcronym":"ARC","InsFSN":"Universiteit Gent; Faculteit Bio-ingenieurswetenschappen; Vakgroep Dierwetenschappen en Aquatische Ecologie; Laboratorium voor Aquacultuur en Artemia Reference Center","ORCID":null,"PersID":35,"InsID":22}],"mapdetails":null,"datasets":null,"monographs":null,"monparts":null,"serparts":null,"BEntOpen":null,"BEntPrivate":null,"availability":[{"BInstID":278833,"LibID":36,"BRefID":19614,"EmbargoDate":null,"FullEmbargoDate":null,"PhysMedID":16,"hasOCRd":1,"ShelfLocCode":"278833","RFID":null,"PaidValue":null,"Medium":"Server","Description":null,"Acronym":"VLIZ","Library":"Vlaams Instituut voor de Zee","DutchTerm":"Open Marien Archief","URL":null,"ClassifID":235,"Classification":"Open Marine Archive","ReqLink":null,"ClassifTypID":5,"URLLocation":"https://www.vliz.be/imisdocs/publications/","SubDir":0,"InternalReq":0,"LoggedInReq":0,"Disclaimer":"Disclaimer_OMA","DutchDisclaimer":null,"FileFormat":".pdf","FileDescr":"pdf","InsPub":1,"InsID":36,"FileFormID":6,"LendableFlag":1,"PublicFlag":1,"orderLib":"A","Notes":null,"AccConID":null,"AccessConstraint":null,"LicURL":null}],"litstyles":null,"thespers":null,"arch2discl":null,"SERpubls":[{"PublName":"Elsevier","City":"Amsterdam; London; New York; Oxford; Tokyo"}],"MONpubls":null,"pictures":[],"thestermsPath":[{"ThesaurusTerm":"Recirculating systems","ThestID":6776,"Acronym":"ASFA","ThesTermPath":"Aquaculture systems > Recirculating systems"},{"ThesaurusTerm":"Aquaculture techniques","ThestID":489,"Acronym":"ASFA","ThesTermPath":"Aquaculture techniques"},{"ThesaurusTerm":"Dissolved oxygen","ThestID":2383,"Acronym":"ASFA","ThesTermPath":"Chemical elements > Nonmetals > Atmospheric gases > Oxygen > Dissolved gases > Dissolved oxygen"},{"ThesaurusTerm":"Nitrification","ThestID":5563,"Acronym":"ASFA","ThesTermPath":"Chemical reactions > Nitrification"},{"ThesaurusTerm":"Water quality control","ThestID":9126,"Acronym":"ASFA","ThesTermPath":"Control > Quality control > Water quality control"},{"ThesaurusTerm":"Ozone","ThestID":5947,"Acronym":"ASFA","ThesTermPath":"Fluids > Gases > Atmospheric gases > Ozone"},{"ThesaurusTerm":"Suspended particulate matter","ThestID":8283,"Acronym":"ASFA","ThesTermPath":"Particulates > Suspended particulate matter"},{"ThesaurusTerm":"Recirculation","ThestID":78009,"Acronym":"CSA","ThesTermPath":"Recirculation"}],"thestermsASFA":[{"ThesaurusTerm":"Aquaculture techniques"},{"ThesaurusTerm":"Dissolved oxygen"},{"ThesaurusTerm":"Nitrification"},{"ThesaurusTerm":"Ozone"},{"ThesaurusTerm":"Recirculating systems"},{"ThesaurusTerm":"Recirculation"},{"ThesaurusTerm":"Suspended particulate matter"},{"ThesaurusTerm":"Water quality control"}],"taxtermsASFA":[{"TaxTerm":"Bacteria"},{"TaxTerm":"Brachionus plicatilis"},{"TaxTerm":"Rotifera"}],"geotermsASFA":null,"collections":[{"Collection":"OMA - Open Marien Archief","ShortName":"OMA"}],"conf":null,"proj":null,"Physdatasets":null,"spcols":{"222":{"SpName":"BMB - Belgische Mariene Bibliografie","SpColID":222,"ParSpColID":null,"TopParID":null,"ShortName":"BMB","URLLocation":null,"LibID":36,"OpenRepoFlag":null,"SpTypID":null,"TopParIDNotWebsite":null,"SpColPath":"BMB"},"221":{"SpName":"OMA - Open Marien Archief","SpColID":221,"ParSpColID":null,"TopParID":null,"ShortName":"OMA","URLLocation":null,"LibID":36,"OpenRepoFlag":1,"SpTypID":null,"TopParIDNotWebsite":null,"SpColPath":"OMA"}},"doi":null,"publs":null,"serparttypes":null,"monauthors":null,"MParts":null,"SParts":null,"hLibs":null,"langs":[{"BEntID":19614,"AbstractFlag":0,"LangID":15,"LangCode":"en","Lang":"English","DutchTerm":"Engels","LangCodeExtended":"eng"},{"BEntID":19614,"AbstractFlag":1,"LangID":15,"LangCode":"en","Lang":"English","DutchTerm":"Engels","LangCodeExtended":"eng"}],"urls":[{"URL":"https://dx.doi.org/10.1016/S0044-8486(01)00532-4","externalID":"10.1016/S0044-8486(01)00532-4","URLTypeCode":"DOI","URLID":21143,"URLTypID":13,"URLType":"DOI","URLPrefix":"http://dx.doi.org/"}],"thesterms":[{"ThesaurusTerm":"Aquaculture techniques","ThestID":489,"Acronym":"ASFA","ThesTypID":1,"ThesType":"ASFA Thesaurus List"},{"ThesaurusTerm":"Dissolved oxygen","ThestID":2383,"Acronym":"ASFA","ThesTypID":1,"ThesType":"ASFA Thesaurus List"},{"ThesaurusTerm":"Nitrification","ThestID":5563,"Acronym":"ASFA","ThesTypID":1,"ThesType":"ASFA Thesaurus List"},{"ThesaurusTerm":"Ozone","ThestID":5947,"Acronym":"ASFA","ThesTypID":1,"ThesType":"ASFA Thesaurus List"},{"ThesaurusTerm":"Recirculating systems","ThestID":6776,"Acronym":"ASFA","ThesTypID":1,"ThesType":"ASFA Thesaurus List"},{"ThesaurusTerm":"Recirculation","ThestID":78009,"Acronym":"CSA","ThesTypID":2,"ThesType":"CSA Technology Research Database Master Thesaurus"},{"ThesaurusTerm":"Suspended particulate matter","ThestID":8283,"Acronym":"ASFA","ThesTypID":1,"ThesType":"ASFA Thesaurus List"},{"ThesaurusTerm":"Water quality control","ThestID":9126,"Acronym":"ASFA","ThesTypID":1,"ThesType":"ASFA Thesaurus List"}],"taxterms":[{"TaxTerm":"Bacteria","AphiaID":6,"TaxtID":11315},{"TaxTerm":"Brachionus plicatilis","AphiaID":134982,"TaxtID":23305},{"TaxTerm":"Rotifera","AphiaID":14260,"TaxtID":16699}],"geoterms":null,"othterms":[{"OtherTerm":"Rotifersozone","OthtID":10262}],"asfacodes":null,"asfa2codes":null,"thestermsFRIS":[{"ThesaurusTerm":"Aquaculture techniques","DutchTerm":null,"ThestID":489,"Acronym":"ASFA","ThesTypID":1,"ThesType":"ASFA Thesaurus List"},{"ThesaurusTerm":"Dissolved oxygen","DutchTerm":"Opgeloste zuurstof","ThestID":2383,"Acronym":"ASFA","ThesTypID":1,"ThesType":"ASFA Thesaurus List"},{"ThesaurusTerm":"Nitrification","DutchTerm":"Nitrificatie","ThestID":5563,"Acronym":"ASFA","ThesTypID":1,"ThesType":"ASFA Thesaurus List"},{"ThesaurusTerm":"Ozone","DutchTerm":null,"ThestID":5947,"Acronym":"ASFA","ThesTypID":1,"ThesType":"ASFA Thesaurus List"},{"ThesaurusTerm":"Recirculating systems","DutchTerm":null,"ThestID":6776,"Acronym":"ASFA","ThesTypID":1,"ThesType":"ASFA Thesaurus List"},{"ThesaurusTerm":"Recirculation","DutchTerm":null,"ThestID":78009,"Acronym":"CSA","ThesTypID":2,"ThesType":"CSA Technology Research Database Master Thesaurus"},{"ThesaurusTerm":"Suspended particulate matter","DutchTerm":"Gesuspendeerd particulair materiaal","ThestID":8283,"Acronym":"ASFA","ThesTypID":1,"ThesType":"ASFA Thesaurus List"},{"ThesaurusTerm":"Water quality control","DutchTerm":"Waterkwaliteitscontrole","ThestID":9126,"Acronym":"ASFA","ThesTypID":1,"ThesType":"ASFA Thesaurus List"}],"taxtermsFRIS":[{"TaxTerm":"Bacteria","DutchTerm":null,"AphiaID":6,"TaxtID":11315},{"TaxTerm":"Brachionus plicatilis","DutchTerm":null,"AphiaID":134982,"TaxtID":23305},{"TaxTerm":"Rotifera","DutchTerm":"Raderdiertjes","AphiaID":14260,"TaxtID":16699}],"geotermsFRIS":null,"othtermsFRIS":[{"OtherTerm":"Rotifersozone","DutchTerm":null,"OthtID":10262}],"resmessage":"","complete":1,"sessions":{"newSesName":"Haspeslagh, Jan, J.","newSesDate":{"date":"2001-10-12 08:40:20.620000","timezone_type":3,"timezone":"Europe/Brussels"},"updSesName":"Bouchti, Zohra, Z.","updSesDate":{"date":"2015-10-27 12:43:04.720000","timezone_type":3,"timezone":"Europe/Brussels"}}}
