{"refrec":{"BRefID":329357,"RR":"<b>Vanneste, D.</b> (2018). Overflow and wave overtopping over broad quay walls modeled with OpenFOAM [POSTER]. Presented at the ICCE 2018 conference at Baltimore. Flanders Hydraulics Research: Antwerp. 1 poster pp.","BEntID":322963,"PublicFlag":1,"CheckedFlag":0,"wosflag":0,"vabbflag":0,"RefStringPartII":". Presented at the ICCE 2018 conference at Baltimore. Flanders Hydraulics Research: Antwerp.  1 poster pp.","DocTypID":5,"DocType":"Book/Monograph","MarineFlag":0,"FreshFlag":0,"BrackishFlag":0,"TerrestrialFlag":0,"Authorstring":"Vanneste, D.","OrigTitleTranslFlag":0,"Authorstringtrunc":"Vanneste, D.","Englishabstract":"AbstractIn the framework of the EU Floods Directive, Flanders Hydraulics Research (FHR) is performing flood modeling studies to evaluate the flood risk along the Belgian coast due to extreme storm surges on the North Sea. Thereto, amongst others, the failure behavior of quay walls in the coastal ports must be determined. Computing the landward non-impulsive wave overtopping discharge over a broad quay, in some cases combined with overflow, on which a flood wall can be present at large distance [O (100 m)] from the front edge poses a particular challenge. This matter, to the authors’ knowledge, is not covered in existing literature, e.g. the European Overtopping Manual. It is also not possible to apply the method for reduction of wave overtopping over a wide crest according to Verwaest et al. (2010), since it was developed for breaking waves on a shallow foreshore overtopping a sloping dike, requiring the determination of a run-up level. It is clear that the landward water flow on the quay should be investigated in more detail, as it is characterized by bottom friction and possible inertia due interaction with the flow reflected at the flood wall. To this end, the CFD toolbox OpenFOAM is used to model the final discharges at the landward side of the quay.","AbstractOtherLang":null,"BibLvlCode":"M","StandardTitle":"Overflow and wave overtopping over broad quay walls modeled with OpenFOAM [POSTER]","OrigTitleLangCode":"en","OrigTitleLangCodeExtended":"eng","OrigTitleLangID":15,"DateLastModified":{"date":"2026-04-22 01:42:02.299298","timezone_type":1,"timezone":"+02:00"},"UserAccessRight":null,"UserAccID":null,"AuthorKeywords":"Quay walls","OtherDescriptors":null,"Notes":null,"AnaPub":null,"MonPub":2018,"DateUpdate":"2020-09-15","DateCreate":"2020-09-15","SecASFANote":null,"ConfID":null,"PeerRev":0,"VlizCoreFlag":1,"WoScode":null,"VABBcode":null,"OpenAcc":0},"refs":null,"anarec":null,"monrec":{"MonID":329357,"ISBN":null,"PubliDate":2018,"IssueDate":null,"Volume":null,"Issue":null,"Pagination":"1 poster","Place":"Antwerp","Edition":"Presented at the ICCE 2018 conference at Baltimore","BRefXtra":null,"BRefXtraRR":null,"SerID":null,"SerRR":null,"Ser2BRefID":null,"Ser2RR":null,"StandardTitleSer":null,"ISSN":null,"AbbrevSer":null,"Degree":null,"ThesisID":null,"InsID":null,"Acronym":null,"FullStandardName":null,"ToPubliDate":null,"SerNotes":null,"eISBN":null,"Pages":null},"serrec":null,"relations":null,"relationsRev":null,"addrec":null,"othpubs":null,"ownerships":null,"authors":[{"AutName":"Vanneste","Firstname":"Dieter","Initials":"D.","Affiliation":"Flanders Hydraulics Research","Discriminator":null,"CorporateFlag":0,"BEntID":322963,"AutID":414435,"OrderNr":1,"DegrID":null,"EditorFlag":0,"CorrespFlag":0,"IllustratorFlag":0,"ReviserFlag":0,"TranslatorFlag":0,"InsAcronym":"WL","InsFSN":"Vlaamse overheid; Beleidsdomein Mobiliteit en Openbare Werken; Vlaams Ministerie Mobiliteit en Openbare Werken; Departement Mobiliteit en Openbare Werken; Waterbouwkundig Laboratorium","ORCID":"0000-0001-6894-8357","PersID":26917,"InsID":116}],"mapdetails":null,"datasets":null,"monographs":null,"monparts":null,"serparts":null,"BEntOpen":322963,"BEntPrivate":null,"availability":[{"BInstID":351092,"LibID":2706,"BRefID":329357,"EmbargoDate":null,"FullEmbargoDate":null,"PhysMedID":16,"hasOCRd":1,"ShelfLocCode":"351092","RFID":null,"PaidValue":null,"Medium":"Server","Description":"Open Archive Documents","Acronym":"WL","Library":"Waterbouwkundig Laboratorium","DutchTerm":"Open Archief","URL":null,"ClassifID":223,"Classification":"Open Repository","ReqLink":null,"ClassifTypID":2,"URLLocation":"https://www.vliz.be/imisdocs/publications/","SubDir":1,"InternalReq":0,"LoggedInReq":0,"Disclaimer":"Disclaimer_OWA","DutchDisclaimer":null,"FileFormat":".pdf","FileDescr":"pdf","InsPub":1,"InsID":116,"FileFormID":6,"LendableFlag":null,"PublicFlag":1,"orderLib":"Waterbouwkundig Laboratorium","Notes":null,"AccConID":null,"AccessConstraint":null,"LicURL":null}],"litstyles":[{"LitStyID":42,"Style":"Poster"}],"thespers":null,"arch2discl":462,"SERpubls":null,"MONpubls":null,"pictures":[],"thestermsPath":[{"ThesaurusTerm":"Modelling","ThestID":5269,"Acronym":"ASFA","ThesTermPath":"Modelling"},{"ThesaurusTerm":"Numerical models","ThestID":5621,"Acronym":"ASFA","ThesTermPath":"Numerical models"},{"ThesaurusTerm":"Wave overtopping","ThestID":9218,"Acronym":"ASFA","ThesTermPath":"Wave overtopping"}],"thestermsASFA":[{"ThesaurusTerm":"Modelling"}],"taxtermsASFA":null,"geotermsASFA":null,"collections":[{"Collection":"Waterbouwkundig Laboratorium","ShortName":"WL"}],"conf":null,"proj":null,"Physdatasets":null,"spcols":{"994":{"SpName":"Kustbescherming","SpColID":994,"ParSpColID":130,"TopParID":130,"ShortName":null,"URLLocation":null,"LibID":2706,"OpenRepoFlag":null,"SpTypID":null,"TopParIDNotWebsite":null,"SpColPath":"WL/Kustbescherming"},"462":{"SpName":"OpenDocs:OWA","SpColID":462,"ParSpColID":130,"TopParID":130,"ShortName":"OWA","URLLocation":"https://documentatiecentrum.watlab.be/owa/imis.php?module=ref&refid=","LibID":2706,"OpenRepoFlag":1,"SpTypID":null,"TopParIDNotWebsite":null,"SpColPath":"WL/OWA"},"130":{"SpName":"Waterbouwkundig Laboratorium","SpColID":130,"ParSpColID":null,"TopParID":null,"ShortName":"WL","URLLocation":null,"LibID":2706,"OpenRepoFlag":null,"SpTypID":1,"TopParIDNotWebsite":null,"SpColPath":"WL"},"1025":{"SpName":"WL expert","SpColID":1025,"ParSpColID":null,"TopParID":null,"ShortName":"WL expert","URLLocation":null,"LibID":null,"OpenRepoFlag":null,"SpTypID":null,"TopParIDNotWebsite":null,"SpColPath":"WL expert"},"360":{"SpName":"WL Staf Publicaties","SpColID":360,"ParSpColID":130,"TopParID":130,"ShortName":"wl stafpublicaties","URLLocation":null,"LibID":null,"OpenRepoFlag":null,"SpTypID":null,"TopParIDNotWebsite":null,"SpColPath":"WL/wl stafpublicaties"}},"doi":null,"publs":[{"PublID":3980,"PublName":"Flanders Hydraulics Research","InsID":116,"PersID":null,"INBOID":null,"OrderNr":1}],"serparttypes":null,"monauthors":null,"MParts":null,"SParts":null,"hLibs":null,"langs":[{"BEntID":322963,"AbstractFlag":0,"LangID":15,"LangCode":"en","Lang":"English","DutchTerm":"Engels","LangCodeExtended":"eng"},{"BEntID":322963,"AbstractFlag":1,"LangID":15,"LangCode":"en","Lang":"English","DutchTerm":"Engels","LangCodeExtended":"eng"}],"urls":null,"thesterms":[{"ThesaurusTerm":"Modelling","ThestID":5269,"Acronym":"ASFA","ThesTypID":1,"ThesType":"ASFA Thesaurus List"},{"ThesaurusTerm":"Numerical models","ThestID":5621,"Acronym":"ASFA","ThesTypID":1,"ThesType":"ASFA Thesaurus List"},{"ThesaurusTerm":"Wave overtopping","ThestID":9218,"Acronym":"ASFA","ThesTypID":1,"ThesType":"ASFA Thesaurus List"}],"taxterms":null,"geoterms":null,"othterms":null,"asfacodes":null,"asfa2codes":null,"thestermsFRIS":[{"ThesaurusTerm":"Modelling","DutchTerm":"Modellering","ThestID":5269,"Acronym":"ASFA","ThesTypID":1,"ThesType":"ASFA Thesaurus List"},{"ThesaurusTerm":"Numerical models","DutchTerm":"Numerieke modellen","ThestID":5621,"Acronym":"ASFA","ThesTypID":1,"ThesType":"ASFA Thesaurus List"},{"ThesaurusTerm":"Wave overtopping","DutchTerm":"Golfoverslag","ThestID":9218,"Acronym":"ASFA","ThesTypID":1,"ThesType":"ASFA Thesaurus List"}],"taxtermsFRIS":null,"geotermsFRIS":null,"othtermsFRIS":null,"resmessage":"","complete":1,"sessions":{"newSesName":"Cerpentier, Steven, S.","newSesDate":{"date":"2020-09-15 14:39:29.323000","timezone_type":3,"timezone":"Europe/Brussels"},"updSesName":"Cerpentier, Steven, S.","updSesDate":{"date":"2020-09-15 14:39:29.323000","timezone_type":3,"timezone":"Europe/Brussels"}}}