{"refrec":{"BRefID":352724,"RR":"<b>Meire, D.; Vandenbruwaene, W.; De Bruyn, L.; Thant, S.; Vereecken, H.; Claeys, S.; Deschamps, M.</b> (2022). Bepaling saliniteit op basis van conductiviteits- en temperatuursmetingen: rekenmethodiek en gevoeligheidsanalyse. Versie 4.0. <i>WL Rapporten</i>, 17_119_1. Waterbouwkundig Laboratorium: Antwerpen. X, 29 + 8 bijl. pp. <a href=\"https://dx.doi.org/10.48607/100\" target=\"_blank\">https://dx.doi.org/10.48607/100</a>","BEntID":350433,"PublicFlag":1,"CheckedFlag":0,"wosflag":0,"vabbflag":0,"RefStringPartII":". Versie 4.0. <i>WL Rapporten</i>, 17_119_1. Waterbouwkundig Laboratorium: Antwerpen.  X, 29 + 8 bijl. pp. <a href=\"https://dx.doi.org/10.48607/100\" target=\"_blank\">https://dx.doi.org/10.48607/100</a>","DocTypID":13,"DocType":"Reports","MarineFlag":0,"FreshFlag":0,"BrackishFlag":0,"TerrestrialFlag":0,"Authorstring":"Meire, D.; Vandenbruwaene, W.; De Bruyn, L.; Thant, S.; Vereecken, H.; Claeys, S.; Deschamps, M.","OrigTitleTranslFlag":0,"Authorstringtrunc":"Meire, D. <i>et al.</i>","Englishabstract":null,"AbstractOtherLang":"Het WL-HIC registreert hoogfrequent conductiviteit en temperatuur om de saliniteit in de waterwegen te berekenen op basis van de UNESCO formule. Staalanalyse toont aan dat het verschil tussen berekende UNESCO saliniteit en de werkelijke saliniteit minder dan 5% bedraagt. De continue conductiviteitsensoren die WL-HIC gebruikt om saliniteit berekenen zijn dus representatief voor de werkelijke saliniteit. Enkel voor de laagste zoutgehaltes (< 2‰, nagenoeg zoet water) onderschat de berekende saliniteit sterk de werkelijke saliniteit. Staalanalyse toont verder aan dat voor de verschillende type conductiviteitsensoren het verschil met de referentie over het algemeen minder dan 10% bedraagt. RBR, Valeport en Seaguard sensoren zijn hierbij het meest in overeenstemming met de referentie. Ook de YSI toestellen zijn in goede overeenstemming met de referentie, maar daar is het type kalibratie erg van belang. ","BibLvlCode":"MS","StandardTitle":"Bepaling saliniteit op basis van conductiviteits- en temperatuursmetingen: rekenmethodiek en gevoeligheidsanalyse","OrigTitleLangCode":"nl","OrigTitleLangCodeExtended":"dut","OrigTitleLangID":41,"DateLastModified":{"date":"2026-04-17 01:41:05.351938","timezone_type":1,"timezone":"+02:00"},"UserAccessRight":null,"UserAccID":null,"AuthorKeywords":null,"OtherDescriptors":null,"Notes":null,"AnaPub":null,"MonPub":2022,"DateUpdate":"2023-05-30","DateCreate":"2022-06-20","SecASFANote":null,"ConfID":null,"PeerRev":0,"VlizCoreFlag":0,"WoScode":null,"VABBcode":null,"OpenAcc":0},"refs":null,"anarec":null,"monrec":{"MonID":352724,"ISBN":null,"PubliDate":2022,"IssueDate":null,"Volume":"17_119_1","Issue":null,"Pagination":"X, 29 + 8 bijl.","Place":"Antwerpen","Edition":"Versie 4.0","BRefXtra":null,"BRefXtraRR":null,"SerID":24938,"SerRR":"WL Rapporten. Waterbouwkundig Laboratorium: Antwerpen. ","Ser2BRefID":null,"Ser2RR":null,"StandardTitleSer":"WL Rapporten","ISSN":null,"AbbrevSer":null,"Degree":null,"ThesisID":null,"InsID":null,"Acronym":null,"FullStandardName":null,"ToPubliDate":null,"SerNotes":null,"eISBN":null,"Pages":29},"serrec":null,"relations":null,"relationsRev":null,"addrec":null,"othpubs":null,"ownerships":null,"authors":[{"AutName":"Meire","Firstname":"Dieter","Initials":"D.","Affiliation":null,"Discriminator":null,"CorporateFlag":0,"BEntID":350433,"AutID":234909,"OrderNr":1,"DegrID":null,"EditorFlag":0,"CorrespFlag":0,"IllustratorFlag":0,"ReviserFlag":0,"TranslatorFlag":0,"InsAcronym":null,"InsFSN":null,"ORCID":"0009-0001-5093-9054","PersID":27163,"InsID":null},{"AutName":"Vandenbruwaene","Firstname":"Wouter","Initials":"W.","Affiliation":null,"Discriminator":null,"CorporateFlag":0,"BEntID":350433,"AutID":79785,"OrderNr":2,"DegrID":null,"EditorFlag":0,"CorrespFlag":0,"IllustratorFlag":0,"ReviserFlag":0,"TranslatorFlag":0,"InsAcronym":null,"InsFSN":null,"ORCID":"0000-0003-3779-6076","PersID":20485,"InsID":null},{"AutName":"De Bruyn","Firstname":"Lia","Initials":"L.","Affiliation":null,"Discriminator":null,"CorporateFlag":0,"BEntID":350433,"AutID":81120,"OrderNr":3,"DegrID":null,"EditorFlag":0,"CorrespFlag":0,"IllustratorFlag":0,"ReviserFlag":0,"TranslatorFlag":0,"InsAcronym":null,"InsFSN":null,"ORCID":"0009-0009-6197-2763","PersID":19356,"InsID":null},{"AutName":"Thant","Firstname":"Silvy","Initials":"S.","Affiliation":"Antea Group Belgium","Discriminator":null,"CorporateFlag":0,"BEntID":350433,"AutID":236710,"OrderNr":4,"DegrID":null,"EditorFlag":0,"CorrespFlag":0,"IllustratorFlag":0,"ReviserFlag":0,"TranslatorFlag":0,"InsAcronym":null,"InsFSN":null,"ORCID":null,"PersID":31027,"InsID":null},{"AutName":"Vereecken","Firstname":"Hans","Initials":"H.","Affiliation":null,"Discriminator":null,"CorporateFlag":0,"BEntID":350433,"AutID":63993,"OrderNr":5,"DegrID":null,"EditorFlag":0,"CorrespFlag":0,"IllustratorFlag":0,"ReviserFlag":0,"TranslatorFlag":0,"InsAcronym":null,"InsFSN":null,"ORCID":"0009-0007-3780-2436","PersID":5188,"InsID":null},{"AutName":"Claeys","Firstname":"Styn","Initials":"S.","Affiliation":"Flanders Hydraulics Research","Discriminator":null,"CorporateFlag":0,"BEntID":350433,"AutID":199371,"OrderNr":6,"DegrID":null,"EditorFlag":0,"CorrespFlag":0,"IllustratorFlag":0,"ReviserFlag":0,"TranslatorFlag":0,"InsAcronym":"WL","InsFSN":"Vlaamse overheid; Beleidsdomein Mobiliteit en Openbare Werken; Vlaams Ministerie Mobiliteit en Openbare Werken; Departement Mobiliteit en Openbare Werken; Waterbouwkundig Laboratorium","ORCID":"0000-0003-1188-7877","PersID":3498,"InsID":116},{"AutName":"Deschamps","Firstname":"Maarten","Initials":"M.","Affiliation":null,"Discriminator":null,"CorporateFlag":0,"BEntID":350433,"AutID":59595,"OrderNr":7,"DegrID":null,"EditorFlag":0,"CorrespFlag":0,"IllustratorFlag":0,"ReviserFlag":0,"TranslatorFlag":0,"InsAcronym":null,"InsFSN":null,"ORCID":"0000-0001-6654-4404","PersID":11355,"InsID":null}],"mapdetails":null,"datasets":null,"monographs":null,"monparts":null,"serparts":null,"BEntOpen":350433,"BEntPrivate":null,"availability":[{"BInstID":378393,"LibID":2706,"BRefID":352724,"EmbargoDate":null,"FullEmbargoDate":null,"PhysMedID":16,"hasOCRd":1,"ShelfLocCode":"378393","RFID":null,"PaidValue":null,"Medium":"Server","Description":"Open Archive Documents","Acronym":"WL","Library":"Waterbouwkundig Laboratorium","DutchTerm":"Open Archief","URL":null,"ClassifID":223,"Classification":"Open Repository","ReqLink":null,"ClassifTypID":2,"URLLocation":"https://www.vliz.be/imisdocs/publications/","SubDir":1,"InternalReq":0,"LoggedInReq":0,"Disclaimer":"Disclaimer_OWA","DutchDisclaimer":null,"FileFormat":".pdf","FileDescr":"pdf","InsPub":1,"InsID":116,"FileFormID":6,"LendableFlag":null,"PublicFlag":1,"orderLib":"Waterbouwkundig Laboratorium","Notes":null,"AccConID":null,"AccessConstraint":null,"LicURL":null}],"litstyles":[{"LitStyID":20,"Style":"Project report"}],"thespers":null,"arch2discl":462,"SERpubls":[{"PublName":"Waterbouwkundig Laboratorium","Place":"Antwerpen"}],"MONpubls":null,"pictures":[{"pic_id":151819,"Typ":7,"Descr":"From reference","imis_show":1,"preferred":1,"URL":"/en/imis?page=image&pic=151819","ext":"jpg","url":"https://images.vliz.be/thumbs/151819_bepaling-saliniteit-op-basis-van-conductiviteits--en-temperatuursmetingen-rekenmethodiek-en-gevoeligheidsanalyse.jpg"}],"thestermsPath":[{"ThesaurusTerm":"Conductivity","ThestID":57877,"Acronym":"CSA","ThesTermPath":"Conductivity"},{"ThesaurusTerm":"Unesco","ThestID":130138,"Acronym":"CAB","ThesTermPath":"Organizations > International organizations > Un > Unesco"},{"ThesaurusTerm":"Salinity","ThestID":7093,"Acronym":"ASFA","ThesTermPath":"Properties > Chemical properties > Salinity"},{"ThesaurusTerm":"Fysico-chemical parameters","ThestID":170044,"Acronym":"WL_KD","ThesTermPath":"Water management > Monitoring-networks > Fysico-chemical parameters"},{"ThesaurusTerm":"Sensitivity analysis","ThestID":170026,"Acronym":"WL_KD","ThesTermPath":"Water management > Statistics > Sensitivity analysis"},{"ThesaurusTerm":"Saline intrusion","ThestID":170024,"Acronym":"WL_KD","ThesTermPath":"Water management > Water quality > Saline intrusion"}],"thestermsASFA":[{"ThesaurusTerm":"Conductivity"},{"ThesaurusTerm":"Fysico-chemical parameters"},{"ThesaurusTerm":"Saline intrusion"},{"ThesaurusTerm":"Salinity"},{"ThesaurusTerm":"Sensitivity analysis"},{"ThesaurusTerm":"Unesco"}],"taxtermsASFA":null,"geotermsASFA":null,"collections":[{"Collection":"Waterbouwkundig Laboratorium","ShortName":"WL"}],"conf":null,"proj":[{"ProID":5225,"Acronym":null,"ProStandardTitle":"\tChloridegehalte - saliniteit - conductiviteit in het Schelde-estuarium: hoe te meten, te analyseren en te rapporteren","BYear":2018,"BMonth":1,"EYear":2022,"EMonth":8,"FP7Code":null,"RelID":1,"Relation":"Result","DutchTerm":"Is resultaat van"}],"Physdatasets":null,"spcols":{"1020":{"SpName":"FRIS (WL)","SpColID":1020,"ParSpColID":130,"TopParID":130,"ShortName":"FRIS (WL)","URLLocation":null,"LibID":2706,"OpenRepoFlag":null,"SpTypID":null,"TopParIDNotWebsite":null,"SpColPath":"WL/FRIS (WL)"},"462":{"SpName":"OpenDocs:OWA","SpColID":462,"ParSpColID":130,"TopParID":130,"ShortName":"OWA","URLLocation":"https://documentatiecentrum.watlab.be/owa/imis.php?module=ref&refid=","LibID":2706,"OpenRepoFlag":1,"SpTypID":null,"TopParIDNotWebsite":null,"SpColPath":"WL/OWA"},"130":{"SpName":"Waterbouwkundig Laboratorium","SpColID":130,"ParSpColID":null,"TopParID":null,"ShortName":"WL","URLLocation":null,"LibID":2706,"OpenRepoFlag":null,"SpTypID":1,"TopParIDNotWebsite":null,"SpColPath":"WL"},"1025":{"SpName":"WL expert","SpColID":1025,"ParSpColID":null,"TopParID":null,"ShortName":"WL expert","URLLocation":null,"LibID":null,"OpenRepoFlag":null,"SpTypID":null,"TopParIDNotWebsite":null,"SpColPath":"WL expert"},"361":{"SpName":"WL Rapporten","SpColID":361,"ParSpColID":130,"TopParID":130,"ShortName":"wl rapporten","URLLocation":null,"LibID":2706,"OpenRepoFlag":null,"SpTypID":null,"TopParIDNotWebsite":null,"SpColPath":"WL/wl rapporten"}},"doi":{"DOIID":696,"DOI":"10.48607/100","fullDOI":"https://dx.doi.org/10.48607/100"},"publs":[{"PublID":2030,"PublName":"Waterbouwkundig Laboratorium","InsID":116,"PersID":null,"INBOID":6434,"OrderNr":1}],"serparttypes":null,"monauthors":null,"MParts":null,"SParts":null,"hLibs":null,"langs":[{"BEntID":350433,"AbstractFlag":0,"LangID":41,"LangCode":"nl","Lang":"Dutch","DutchTerm":"Nederlands","LangCodeExtended":"dut"},{"BEntID":350433,"AbstractFlag":1,"LangID":41,"LangCode":"nl","Lang":"Dutch","DutchTerm":"Nederlands","LangCodeExtended":"dut"}],"urls":null,"thesterms":[{"ThesaurusTerm":"Conductivity","ThestID":57877,"Acronym":"CSA","ThesTypID":2,"ThesType":"CSA Technology Research Database Master Thesaurus"},{"ThesaurusTerm":"Fysico-chemical parameters","ThestID":170044,"Acronym":"WL_KD","ThesTypID":12,"ThesType":"WL Kennisdomein"},{"ThesaurusTerm":"Saline intrusion","ThestID":170024,"Acronym":"WL_KD","ThesTypID":12,"ThesType":"WL Kennisdomein"},{"ThesaurusTerm":"Salinity","ThestID":7093,"Acronym":"ASFA","ThesTypID":1,"ThesType":"ASFA Thesaurus List"},{"ThesaurusTerm":"Sensitivity analysis","ThestID":170026,"Acronym":"WL_KD","ThesTypID":12,"ThesType":"WL Kennisdomein"},{"ThesaurusTerm":"Unesco","ThestID":130138,"Acronym":"CAB","ThesTypID":4,"ThesType":"CAB Thesaurus"}],"taxterms":null,"geoterms":null,"othterms":null,"asfacodes":null,"asfa2codes":null,"thestermsFRIS":[{"ThesaurusTerm":"Conductivity","DutchTerm":null,"ThestID":57877,"Acronym":"CSA","ThesTypID":2,"ThesType":"CSA Technology Research Database Master Thesaurus"},{"ThesaurusTerm":"Fysico-chemical parameters","DutchTerm":"Fysico-chemische parameters","ThestID":170044,"Acronym":"WL_KD","ThesTypID":12,"ThesType":"WL Kennisdomein"},{"ThesaurusTerm":"Saline intrusion","DutchTerm":"Zoutintrusie","ThestID":170024,"Acronym":"WL_KD","ThesTypID":12,"ThesType":"WL Kennisdomein"},{"ThesaurusTerm":"Salinity","DutchTerm":"Saliniteit","ThestID":7093,"Acronym":"ASFA","ThesTypID":1,"ThesType":"ASFA Thesaurus List"},{"ThesaurusTerm":"Sensitivity analysis","DutchTerm":"Gevoeligheidsanalyse","ThestID":170026,"Acronym":"WL_KD","ThesTypID":12,"ThesType":"WL Kennisdomein"},{"ThesaurusTerm":"Unesco","DutchTerm":null,"ThestID":130138,"Acronym":"CAB","ThesTypID":4,"ThesType":"CAB Thesaurus"}],"taxtermsFRIS":null,"geotermsFRIS":null,"othtermsFRIS":null,"resmessage":"","complete":1,"sessions":{"newSesName":"Baertsoen, Claudia, C.","newSesDate":{"date":"2022-06-20 15:45:41.270000","timezone_type":3,"timezone":"Europe/Brussels"},"updSesName":"Cerpentier, Steven, S.","updSesDate":{"date":"2023-05-30 10:47:14.997000","timezone_type":3,"timezone":"Europe/Brussels"}}}