Skip to main content

IMIS

A new integrated search interface will become available in the next phase of marineinfo.org.
For the time being, please use IMIS to search available data

 

[ report an error in this record ]basket (0): add | show Print this page

Reductive amination for LC-MS signal enhancement and confirmation of the presence of Caribbean ciguatoxin-1 in fish
Kryuchkov, F.; Robertson, A.; Mudge, E.M.; Miles, C.O.; Van Gothem, S.; Uhlig, S. (2022). Reductive amination for LC-MS signal enhancement and confirmation of the presence of Caribbean ciguatoxin-1 in fish. Toxins 14(6): 399. https://dx.doi.org/10.3390/toxins14060399
In: Toxins. Multidisciplinary Digital Publishing Institute (MDPI): Basel. e-ISSN 2072-6651, more
Peer reviewed article  

Available in  Authors 

Keyword
    Marine/Coastal
Author keywords
    ciguatoxin; Caribbean ciguatoxin; Girard’s reagent; quaternary ammonium; LC–MS; derivatization

Authors  Top 
  • Kryuchkov, F.
  • Robertson, A.
  • Mudge, E.M.
  • Miles, C.O.
  • Van Gothem, S., more
  • Uhlig, S.

Abstract
    Ciguatera poisoning is a global health concern caused by the consumption of seafood containing ciguatoxins (CTXs). Detection of CTXs poses significant analytical challenges due to their low abundance even in highly toxic fish, the diverse and in-part unclarified structures of many CTX congeners, and the lack of reference standards. Selective detection of CTXs requires methods such as liquid chromatography coupled to tandem mass spectrometry (LC–MS/MS) or high-resolution MS (LC–HRMS). While HRMS data can provide greatly improved resolution, it is typically less sensitive than targeted LC–MS/MS and does not reliably comply with the FDA guidance level of 0.1 µg/kg CTXs in fish tissue that was established for Caribbean CTX-1 (C-CTX-1). In this study, we provide a new chemical derivatization approach employing a fast and simple one-pot derivatization with Girard’s reagent T (GRT) that tags the C-56-ketone intermediate of the two equilibrating C-56 epimers of C-CTX-1 with a quaternary ammonium moiety. This derivatization improved the LC–MS/MS and LC–HRMS responses to C-CTX-1 by approximately 40- and 17-fold on average, respectively. These improvements in sensitivity to the GRT-derivative of C-CTX-1 are attributable to: the improved ionization efficiency caused by insertion of a quaternary ammonium ion; the absence of adduct-ions and water-loss peaks for the GRT derivative in the mass spectrometer, and; the prevention of on-column epimerization (at C-56 of C-CTX-1) by GRT derivatization, leading to much better chromatographic peak shapes. This C-CTX-1–GRT derivatization strategy mitigates many of the shortcomings of current LC–MS analyses for C-CTX-1 by improving instrument sensitivity, while at the same time adding selectivity due to the reactivity of GRT with ketones and aldehydes.

All data in the Integrated Marine Information System (IMIS) is subject to the VLIZ privacy policy Top | Authors